AMETEK 7002-004-KE WDG-V UOP Acid Coated Zirconia Cell


  • Part Number: 7002-004-KE
  • Category: Analyzer Systems
  • Manufacturer: AMETEK
  • Product Origin: Germany / EU Germany / EU
  • Issue Date: 2026-11-26 17:35:33
  • SKU: IS-111611
  • ✓Certified Refurbished & Surplus — Save 30-60% vs New Price
  • ✓Fully Tested & Calibrated — 100% Functional Test & Report Included
  • ✓3-12 Months Warranty — Guaranteed Functional Warranty
  • ✓Fast Global Express Shipping — 3-7 Days Delivery via DHL / FedEx / UPS
Inquire via WhatsApp
New Product
On Request
✓ Original Factory Packaging
✓ Ship by: 2-4 Weeks
Never Used W/O Package
On Request
✓ Open-Box Surplus Stock
✓ Protective Industrial Packaging
✓ Ship by: 3-7 Business Days
Refurbish Grade A
On Request
✓ Inspected & 100% Function Tested
✓ 90%+ Like New Appearance
✓ Certified Refurbished
✓ Ship by: 5-10 Business Days
Refurbish Grade B
On Request
✓ Used, Repaired & Function Tested
✓ Ship by: 4-10 Business Days

Taxonomy Path: Analyzer Systems > Gas Analytics > Gas Analyzer Accessories

AMETEK 7002-004-KE overview
AMETEK 7002-004-KE is the acid coated cell for the Thermox WDG-V UOP analyzer. The WDG-V UOP/RP is the analyzer AMETEK has designed for oxygen measurement in continuous catalytic regeneration (CCR) platforming units, a process the datasheet describes in detail. The datasheet states that dual isolation valves allow the sensor to be replaced without shutting down the CCR process. The AMETEK listing is short and names only the acid coated cell for the WDG-V UOP, so the cell matches the UOP analyzer platform rather than the standard flue gas WDG-V.
The WDG-V UOP/RP is the AMETEK oxygen analyzer for continuous catalytic regeneration (CCR) platforming processes. The datasheet describes a nitrogen-operated aspirator that draws a sample from the catalyst regenerator, a zirconia sensor, Hastelloy probe tube, heated wetted parts and dual isolation valves so the sensor can be replaced without shutting down the process.
Key features of 7002-004-KE
Acid coated zirconia cell for the WDG-V UOP/RP analyzer
Intended for CCR platforming oxygen control
Replaceable through dual isolation valves without a process shutdown (datasheet)
Hastelloy probe tube and 316 SS wetted parts on the analyzer
Different from the standard WDG-V cell 7000-568-SE
Nitrogen-aspirated sampling design
7002-004-KE technical specifications
Item
Detail
Part number
7002-004-KE
Description
Acid coated cell, WDG-V UOP
Analyzer (datasheet)
WDG-V UOP/RP CCR oxygen analyzer
Principle
Zirconium oxide, nitrogen-aspirated
Accuracy (datasheet)
Plus or minus 0.75 percent of measured value or plus or minus 0.05 percent oxygen, whichever is greater
Response (datasheet)
90 percent of a process step change in less than 12 seconds
Principle (datasheet)
Nitrogen-aspirated zirconium oxide net O2 analyzer
Output range
0-1 percent to 0-100 percent O2
Drift
Less than 0.1 percent of cell output per month
Aspirator requirement
Nitrogen, 10-20 scfh
Sample pressure
14.69 psig up to 60 psig
Probe
Hastelloy C, 1

Delivery: UPS, FedEx and DHL Express
International delivery available
Same day shipping for in-stock items on location
Will negotiate custom freight & clearance details
Combined Shipping Policy: We combine shipments to reduce costs for customers purchasing multiple items. After completing your selection, request a consolidated proforma invoice including shipping and handling.
Warranty: All products are covered by Global Valve Hub — Industrial Supplies & Engineering Solutions.
We record a functional test video before shipping.
✓ 3–12 Months Functional Warranty on New, Surplus & Refurbished Parts.
Returns: No-hassle return and replacement policy.
Quick Quotes: Receive Price & Availability Today! Email sales@globalvalvehub.com or WhatsApp +1 332 322 6825.
Payment Options: Wire Transfer (T/T) PayPal Visa MasterCard

Related Products

305121901S
Request Inquiry
More Info
150028X
Request Inquiry
More Info
173435
Request Inquiry
More Info
700-0002-024
Request Inquiry
More Info
305122902S
Request Inquiry
More Info
150030X
Request Inquiry
More Info
↑