Donaldson HRC-T 0220-22000 Hydrogen Dryer and De-Oxo Unit


  • Part Number: HRC-T
  • Category: Compressor & Cooling
  • Manufacturer: Donaldson
  • Product Origin: Germany / EU Germany / EU
  • Issue Date: 2026-11-26 17:35:28
  • SKU: IS-105748
  • ✓Certified Refurbished & Surplus — Save 30-60% vs New Price
  • ✓Fully Tested & Calibrated — 100% Functional Test & Report Included
  • ✓3-12 Months Warranty — Guaranteed Functional Warranty
  • ✓Fast Global Express Shipping — 3-7 Days Delivery via DHL / FedEx / UPS
Inquire via WhatsApp
New Product
On Request
✓ Original Factory Packaging
✓ Ship by: 2-4 Weeks
Never Used W/O Package
On Request
✓ Open-Box Surplus Stock
✓ Protective Industrial Packaging
✓ Ship by: 3-7 Business Days
Refurbish Grade A
On Request
✓ Inspected & 100% Function Tested
✓ 90%+ Like New Appearance
✓ Certified Refurbished
✓ Ship by: 5-10 Business Days
Refurbish Grade B
On Request
✓ Used, Repaired & Function Tested
✓ Ship by: 4-10 Business Days

Taxonomy Path: Compressor & Cooling > Compressors

A hydrogen purification skid with De-Oxo unit and heat-regenerated dryer
The
Donaldson HRC-T
removes moisture, oxygen, liquid and solid particulates from hydrogen. The skid contains a pre-filter, a De-Oxo unit with a catalyst that converts oxygen and hydrogen to water, a two-vessel heat-regenerated adsorption dryer and an afterfilter. It is designed for nominal hydrogen flows up to 22,000 Nm3/h at 16 to 46 bar, and residual water and oxygen content of under 5 ppm each can be achieved depending on sizing and inlet impurities.
The regeneration flow is taken from the main stream, heated, cooled and fed back, so the sheet claims zero loss of hydrogen and 100 percent of the inlet flow at the outlet. The system is assembled on a skid, uses UltraPleat media in its filters and is described as suitable and CE marked for ATEX Zone 2.
Technical specifications
Parameter
Specification
Series
HRC-T 0220 to 22000 with De-Oxo unit
Flow
Up to 22,000 Nm3/h hydrogen
Pressure range
16 to 46 bar
Residual water / oxygen
Below 5 ppm / below 5 ppm (depending on sizing and inlet)
Adsorber vessel
Stainless steel, minimum 1.4541; design 50 bar g, -30 C to +200 C
Piping
Stainless steel or galvanized carbon steel; flanges PN 63
Filter housings
Stainless steel, design 50 bar g, 120 C
Controller
3 ph, 400 V, 50 Hz, IP 54, potential-free alarm and remote on/off
Nominal conditions
30 bar g, 40 C, 100 percent saturated, up to 0.4 percent vol oxygen
Standards
AD 2000, PED 2014/29/EU and 2014/68/EU; ATEX Zone 2
Process stages
Hydrogen enters at the wet gas inlet and passes the pre-filter, a preheater and the De-Oxo catalyst. The catalytic reaction is exothermic, so a precooler and separator cool the gas before it reaches the pressure control valve and the adsorption dryer. One adsorber dries while the other is regenerated with a heated partial stream, and a cooling step follows before the vessels switch.
The dried hydrogen then passes an afterfilter that retains desiccant dust. The sheet names green e

Delivery: UPS, FedEx and DHL Express
International delivery available
Same day shipping for in-stock items on location
Will negotiate custom freight & clearance details
Combined Shipping Policy: We combine shipments to reduce costs for customers purchasing multiple items. After completing your selection, request a consolidated proforma invoice including shipping and handling.
Warranty: All products are covered by Global Valve Hub — Industrial Supplies & Engineering Solutions.
We record a functional test video before shipping.
✓ 3–12 Months Functional Warranty on New, Surplus & Refurbished Parts.
Returns: No-hassle return and replacement policy.
Quick Quotes: Receive Price & Availability Today! Email sales@globalvalvehub.com or WhatsApp +1 332 322 6825.
Payment Options: Wire Transfer (T/T) PayPal Visa MasterCard

Related Products

DF-T
Request Inquiry
More Info
P-SLF
Request Inquiry
More Info
UFM-D30
Request Inquiry
More Info
P568583
Request Inquiry
More Info
S 0035-1450
Request Inquiry
More Info
UFM-P
Request Inquiry
More Info
↑