KRACHT VCG 2 M1F1P2SH Cast Iron Gear Flow Meter 350 bar


  • Part Number: VCG
  • Category: Metering Systems
  • Manufacturer: KRACHT
  • Product Origin: Germany / EU Germany / EU
  • Issue Date: 2026-11-26 17:35:33
  • SKU: IS-113230
  • ✓Certified Refurbished & Surplus — Save 30-60% vs New Price
  • ✓Fully Tested & Calibrated — 100% Functional Test & Report Included
  • ✓3-12 Months Warranty — Guaranteed Functional Warranty
  • ✓Fast Global Express Shipping — 3-7 Days Delivery via DHL / FedEx / UPS
Inquire via WhatsApp
New Product
On Request
✓ Original Factory Packaging
✓ Ship by: 2-4 Weeks
Never Used W/O Package
On Request
✓ Open-Box Surplus Stock
✓ Protective Industrial Packaging
✓ Ship by: 3-7 Business Days
Refurbish Grade A
On Request
✓ Inspected & 100% Function Tested
✓ 90%+ Like New Appearance
✓ Certified Refurbished
✓ Ship by: 5-10 Business Days
Refurbish Grade B
On Request
✓ Used, Repaired & Function Tested
✓ Ship by: 4-10 Business Days

Taxonomy Path: Metering Systems > Flowmeters > Turbine & Positive Displacement Flowmeters

High-pressure cast iron gear meter VCG 2 M1F1P2SH
KRACHT VCG 2 M1F1P2SH is the cast iron relative of the VCA size 2. The housing and cover are spheroidal cast iron GJS-400, the gears are steel, and a multi-layer plain bearing carries the load, which lets the meter work at 350 bar and at media temperatures up to 120 C.
The code reads VCG 2 (size), M (multi-layer plain bearing), 1 (cast iron housing with steel gears), F (FKM seals), 1 (standard coating), P (plate mounting), 2 (two sensors), S (standard pre-amplifier) and H (Hirschmann socket).
Specifications of VCG 2 M1F1P2SH
Parameter
Value
Type code
VCG 2 M1F1P2SH
Geometric tooth volume
2.000 cm3
Measuring range
1.00 to 65 l/min
Measuring unit starting at
0.04 l/min at 100 mm2/s
Resolution per channel
500.00 pulses per litre
Maximum pressure
350 bar
Weight
5.0 kg
Typical accuracy
plus/minus 2.5 percent from 20 mm2/s
Maximum pressure loss
16 bar
Media temperature
-15 to 120 C
Ambient temperature
-10 to 80 C
Viscosity
up to 4,000 mm2/s
Sound pressure level
up to 60 dB(A)
Channels
2, offset 90 degrees plus/minus 30
Supply
12 to 30 V DC
Protection
IP 65
Notes on the table: the 350 bar figure is the maximum pressure of the meter body, while the permissible pressure loss across the measuring unit is a separate limit of 16 bar. The sound pressure level of up to 60 dB(A) is the same as for the aluminium sizes, so the heavier cast iron body does not make the meter noisier. Ambient and media limits differ, and both must be respected.
Why choose VCG 2 M1F1P2SH instead of VCA 2
The tooth volume, range and resolution match the VCA 2, so the hydraulic capacity is the same. What changes is the housing and the rating: 350 bar instead of 200 bar, media up to 120 C instead of 80 C, weight 5.0 kg instead of 1.9 kg and two sensors instead of one. The trade-off is a typical accuracy of plus/minus 2.5 percent against plus/minus 1.0 percent for the aluminium meter.
Against the VCA 5 it offers more than three times the pressure rating at o

Delivery: UPS, FedEx and DHL Express
International delivery available
Same day shipping for in-stock items on location
Will negotiate custom freight & clearance details
Combined Shipping Policy: We combine shipments to reduce costs for customers purchasing multiple items. After completing your selection, request a consolidated proforma invoice including shipping and handling.
Warranty: All products are covered by Global Valve Hub — Industrial Supplies & Engineering Solutions.
We record a functional test video before shipping.
✓ 3–12 Months Functional Warranty on New, Surplus & Refurbished Parts.
Returns: No-hassle return and replacement policy.
Quick Quotes: Receive Price & Availability Today! Email sales@globalvalvehub.com or WhatsApp +1 332 322 6825.
Payment Options: Wire Transfer (T/T) PayPal Visa MasterCard

Related Products

PT 300-A-063-144
Request Inquiry
More Info
MVC
Request Inquiry
More Info
KP 1/4
Request Inquiry
More Info
VC 3
Request Inquiry
More Info
VC 0.2
Request Inquiry
More Info
VCA
Request Inquiry
More Info
↑