LESER Type 821 Modulate Action Pilot-Operated Safety Valve


  • Part Number: Type
  • Category: Fittings & Valves
  • Manufacturer: LESER
  • Product Origin: Germany / EU Germany / EU
  • Issue Date: 2026-11-26 17:35:17
  • SKU: IS-102641
  • ✓Certified Refurbished & Surplus — Save 30-60% vs New Price
  • ✓Fully Tested & Calibrated — 100% Functional Test & Report Included
  • ✓3-12 Months Warranty — Guaranteed Functional Warranty
  • ✓Fast Global Express Shipping — 3-7 Days Delivery via DHL / FedEx / UPS
Inquire via WhatsApp
New Product
On Request
✓ Original Factory Packaging
✓ Ship by: 2-4 Weeks
Never Used W/O Package
On Request
✓ Open-Box Surplus Stock
✓ Protective Industrial Packaging
✓ Ship by: 3-7 Business Days
Refurbish Grade A
On Request
✓ Inspected & 100% Function Tested
✓ 90%+ Like New Appearance
✓ Certified Refurbished
✓ Ship by: 5-10 Business Days
Refurbish Grade B
On Request
✓ Used, Repaired & Function Tested
✓ Ship by: 4-10 Business Days

Taxonomy Path: Fittings & Valves > Safety Relief Valves

API 526 pilot-operated safety valve that opens in proportion to overpressure
The
LESER Type 821
is the modulate action version of the LESER High Efficiency pilot-operated safety valve (POSV). It combines the API 526 main valve with a Series 820 pilot that opens the valve gradually, in proportion to the overpressure, so that only as much mass flow is discharged as is needed to stop the pressure rise. This keeps product loss small and suits services where the medium should not be released to atmosphere in large quantities.
Unlike the pop action Type 811, which is limited to gas, LESER lists the modulate action design for steam, gases and liquids.
Technical specifications
Parameter
Specification
Manufacturer
LESER GmbH & Co. KG
Type
821, Series 820 modulate action pilot
Design standard
API 526
Sizes
1 in. x 2 in. to 8 in. x 10 in. (DN 25 to DN 200)
Orifices
API D to T; Extra Orifice 1 G 2 to 8 T+ 10
Flange ratings
ASME B16.5 CL150 to CL2500; EN 1092-1 PN 10 to PN 400, depending on size (CL2500 / PN 400 marked as in preparation in the catalog)
Body materials
WCB / 1.0619, LCB, CF8M / 1.4408
Full open
At max. 10 % overpressure
Blowdown
Max. 7 %, fixed
Media
Steam, gases and liquids
Back pressure
Up to 70 % of set pressure (main valve outlet rating permitting)
Tightness
Up to 97 % of set pressure
Pilot
Stainless steel pilot; tubing integrated in top plate; backflow preventer in manifold block as standard
Why a pilot-operated valve
In a POSV the system pressure is led to the dome above the main valve piston. Because the dome area is larger than the seat area, the closing force rises as the pressure approaches set point, which is why LESER quotes tightness up to 97 % of set pressure. This allows plants to run closer to set pressure than with a spring-loaded valve. The set pressure is independent of superimposed or built-up back pressure within the operating limits, which matters on long flare headers in refineries and on offshore platforms.
Where inlet pressure loss exceeds

Delivery: UPS, FedEx and DHL Express
International delivery available
Same day shipping for in-stock items on location
Will negotiate custom freight & clearance details
Combined Shipping Policy: We combine shipments to reduce costs for customers purchasing multiple items. After completing your selection, request a consolidated proforma invoice including shipping and handling.
Warranty: All products are covered by Global Valve Hub — Industrial Supplies & Engineering Solutions.
We record a functional test video before shipping.
✓ 3–12 Months Functional Warranty on New, Surplus & Refurbished Parts.
Returns: No-hassle return and replacement policy.
Quick Quotes: Receive Price & Availability Today! Email sales@globalvalvehub.com or WhatsApp +1 332 322 6825.
Payment Options: Wire Transfer (T/T) PayPal Visa MasterCard

Related Products

Type
Request Inquiry
More Info
Type
Request Inquiry
More Info
Type
Request Inquiry
More Info
Type
Request Inquiry
More Info
Type
Request Inquiry
More Info
KUB
Request Inquiry
More Info
↑