Schneider Electric 16906 Acti9 RCCB-ID 100 mA Type AC


  • Part Number: 16906
  • Category: Electrical & Power
  • Manufacturer: Schneider Electric
  • Product Origin: Germany / EU Germany / EU
  • Issue Date: 2026-11-26 17:35:33
  • SKU: IS-110146
  • ✓Certified Refurbished & Surplus — Save 30-60% vs New Price
  • ✓Fully Tested & Calibrated — 100% Functional Test & Report Included
  • ✓3-12 Months Warranty — Guaranteed Functional Warranty
  • ✓Fast Global Express Shipping — 3-7 Days Delivery via DHL / FedEx / UPS
Inquire via WhatsApp
New Product
On Request
✓ Original Factory Packaging
✓ Ship by: 2-4 Weeks
Never Used W/O Package
On Request
✓ Open-Box Surplus Stock
✓ Protective Industrial Packaging
✓ Ship by: 3-7 Business Days
Refurbish Grade A
On Request
✓ Inspected & 100% Function Tested
✓ 90%+ Like New Appearance
✓ Certified Refurbished
✓ Ship by: 5-10 Business Days
Refurbish Grade B
On Request
✓ Used, Repaired & Function Tested
✓ Ship by: 4-10 Business Days

Taxonomy Path: Electrical & Power > Circuit Breakers

16906: Acti9 RCCB-ID 100 mA type AC residual current breaker
The
16906
is a Schneider Electric Acti9 residual current circuit breaker, four pole, rated 125 A, with 100 mA earth-leakage sensitivity and a type AC characteristic. The datasheet names it a residual current circuit breaker ID Fi and lists the device short name as RCCB-ID. our engineering team supplies the 16906 in Oman and the GCC as an independent supplier in Muscat, mostly for distribution boards that need a like-for-like replacement or an extension.
The datasheet, generated on 8 Nov 2026, marks the 16906 as discontinued on 17 Jan 2025. It carries no overcurrent release of its own, so it must be backed by suitable short-circuit protection upstream, and stock should be confirmed before ordering.
Climate limits and enclosure
The datasheet lists IP20 for the device itself and IP40 when it is in a modular enclosure, pollution degree 3 and tropicalisation class 2 to IEC 61008, with relative humidity of 95 % at 55 °C and an operating altitude of 2000 m. The operating temperature range is -25 to 40 °C, with storage from -40 to 85 °C.
The upper operating limit of 40 °C is lower than many Gulf switchrooms reach in summer. Inside a closed board the temperature is higher than ambient, so check the board temperature rather than the room temperature, provide ventilation or air conditioning, and ask us to confirm the datasheet limits for the 16906 if the board runs hot.
What the 100 mA and type AC ratings mean for the 16906
With 100 mA sensitivity it is a mid-level device. It is more tolerant of standing leakage in large installations than a 30 mA unit, and it is typically chosen for equipment or fire-risk protection on larger feeders rather than for personal protection.
Within this group the 16906 is less sensitive than the 30 mA version, so it tolerates the background leakage of groups of motors and filters better. The datasheet lists the protection time delay as instantaneous and the tripping technology as electromechan

Delivery: UPS, FedEx and DHL Express
International delivery available
Same day shipping for in-stock items on location
Will negotiate custom freight & clearance details
Combined Shipping Policy: We combine shipments to reduce costs for customers purchasing multiple items. After completing your selection, request a consolidated proforma invoice including shipping and handling.
Warranty: All products are covered by Global Valve Hub — Industrial Supplies & Engineering Solutions.
We record a functional test video before shipping.
✓ 3–12 Months Functional Warranty on New, Surplus & Refurbished Parts.
Returns: No-hassle return and replacement policy.
Quick Quotes: Receive Price & Availability Today! Email sales@globalvalvehub.com or WhatsApp +1 332 322 6825.
Payment Options: Wire Transfer (T/T) PayPal Visa MasterCard

Related Products

SLAWTXX
Request Inquiry
More Info
ZB4BD5
Request Inquiry
More Info
ZB4BP3S
Request Inquiry
More Info
ZB4BV5
Request Inquiry
More Info
ZB4BW35
Request Inquiry
More Info
Schneider
Request Inquiry
More Info
↑