KRACHT VCA 0.2 U5F4R2SH Dual-Channel Gear Flow Meter


  • Part Number: VCA
  • Category: Metering Systems
  • Manufacturer: KRACHT
  • Product Origin: Germany / EU Germany / EU
  • Issue Date: 2026-11-26 17:35:33
  • SKU: IS-113227
  • ✓Certified Refurbished & Surplus — Save 30-60% vs New Price
  • ✓Fully Tested & Calibrated — 100% Functional Test & Report Included
  • ✓3-12 Months Warranty — Guaranteed Functional Warranty
  • ✓Fast Global Express Shipping — 3-7 Days Delivery via DHL / FedEx / UPS
Inquire via WhatsApp
New Product
On Request
✓ Original Factory Packaging
✓ Ship by: 2-4 Weeks
Never Used W/O Package
On Request
✓ Open-Box Surplus Stock
✓ Protective Industrial Packaging
✓ Ship by: 3-7 Business Days
Refurbish Grade A
On Request
✓ Inspected & 100% Function Tested
✓ 90%+ Like New Appearance
✓ Certified Refurbished
✓ Ship by: 5-10 Business Days
Refurbish Grade B
On Request
✓ Used, Repaired & Function Tested
✓ Ship by: 4-10 Business Days

Taxonomy Path: Metering Systems > Flowmeters > Turbine & Positive Displacement Flowmeters

Direction detection in a compact meter: VCA 0.2 U5F4R2SH
KRACHT VCA 0.2 U5F4R2SH is the only size in the VCA family that combines a plastic plain bearing with two sensors. The two channels are offset by 90 degrees plus/minus 30, so the evaluating electronics can tell which way the oil flows and count four edges per tooth instead of one.
The ordering code reads VCA 0.2, U plastic plain bearing, 5 aluminium housing with steel gears, F FKM seals, 4 hard-coated surface, R pipe connection, 2 two sensors, S standard pre-amplifier and H Hirschmann socket.
Compared with a single-channel meter the extra sensor costs very little in installation effort, because both channels leave through the same plug. The advantage is robustness against sensor noise: if a counter sees both channels change in a consistent order, spurious pulses caused by vibration at standstill can be ignored, which is helpful on machines where the oil column oscillates when a pump stops.
Technical data of VCA 0.2 U5F4R2SH
Parameter
Value
Type code
VCA 0.2 U5F4R2SH
Geometric tooth volume
0.200 cm3
Measuring range
0.25 to 10 l/min
Measuring unit starting at
0.04 l/min at 100 mm2/s
Resolution per channel
5,000.00 pulses per litre
Maximum pressure
200 bar
Maximum pressure loss
10 bar
Weight
0.6 kg
Channels
2, offset 90 degrees plus/minus 30
Typical accuracy
plus/minus 1.0 percent from 20 mm2/s
Media and ambient temperature
-10 to 80 C
Viscosity
up to 4,000 mm2/s
Supply
12 to 30 V DC
Output
PNP / NPN square wave
Protection
IP 65
The datasheet also gives pressure drop curves with viscosity as the parameter. For this size the curve family runs up to 10 l/min, so check your oil’s viscosity at its coldest operating temperature against the chart before finalising the line pressure.
Differences between VCA 0.2 U5F4R2SH and other VCA models
Two numbers separate it from the VCA 0.1: the pressure loss limit is 10 bar rather than 16 bar and the maximum pressure is 200 bar rather than 240 bar. The start-up flow of 0.04 l/mi

Delivery: UPS, FedEx and DHL Express
International delivery available
Same day shipping for in-stock items on location
Will negotiate custom freight & clearance details
Combined Shipping Policy: We combine shipments to reduce costs for customers purchasing multiple items. After completing your selection, request a consolidated proforma invoice including shipping and handling.
Warranty: All products are covered by Global Valve Hub — Industrial Supplies & Engineering Solutions.
We record a functional test video before shipping.
✓ 3–12 Months Functional Warranty on New, Surplus & Refurbished Parts.
Returns: No-hassle return and replacement policy.
Quick Quotes: Receive Price & Availability Today! Email sales@globalvalvehub.com or WhatsApp +1 332 322 6825.
Payment Options: Wire Transfer (T/T) PayPal Visa MasterCard

Related Products

PT 300-A-063-144
Request Inquiry
More Info
MVC
Request Inquiry
More Info
KP 1/4
Request Inquiry
More Info
VC 3
Request Inquiry
More Info
VC 0.2
Request Inquiry
More Info
VCG
Request Inquiry
More Info
↑